Avaliação de um novo sensor de movimento em pacientes com doença pulmonar obstrutiva crônica

dataload.collectionmapped02 - Mestrado - Ciências da Reabilitaçãopt_BR
dataload.filenamenourau2507.pdfpt_BR
dataload.handlemapped123456789/84pt_BR
dataload.idpergamum160754pt_BR
dataload.idvirtuanourauvtls000180438pt_BR
dataload.idvirtuapergamumvtls000180438pt_BR
dataload.idvirtuapergamum.sameurlnourauSIMpt_BR
dataload.linknourauhttp://www.bibliotecadigital.uel.br/document/?code=vtls000180438pt_BR
dataload.linknourau.regularSIMpt_BR
dataload.linknourau.retificadohttp://www.bibliotecadigital.uel.br/document/?code=vtls000180438pt_BR
dataload.linknourau.size64.00pt_BR
dc.contributor.advisorPitta, Fábio de Oliveira [Orientador]pt_BR
dc.contributor.authorSant'Anna, Thaís Jordão Perezpt_BR
dc.contributor.bancaMayer, Anamaria Fleigpt_BR
dc.contributor.bancaProbst, Vanessa Suzianept_BR
dc.coverage.spatialLondrinapt_BR
dc.date.accessioned2024-05-01T14:19:17Z
dc.date.available2024-05-01T14:19:17Z
dc.date.created2012.00pt_BR
dc.date.defesa29.10.2012pt_BR
dc.description.abstractResumo: Pacientes com doença pulmonar obstrutiva crônica (DPOC) são consideravelmente menos ativos na vida diária quando comparados a idosos saudáveis A inatividade está associada a diversas complicações da doença, além de ser considerada o mais importante fator preditor de mortalidade em pacientes com DPOC Por conta disso, sensores de movimento válidos e economicamente acessíveis são necessários para a monitorização da atividade física Objetivos: Avaliar a validade e a reprodutibilidade do sensor de movimento Power Walker 61 (PW) em pacientes com DPOC Métodos: Trinta pacientes com DPOC (17 homens, VEF1 44±17% do predito) foram filmados enquanto realizavam dois protocolos de atividade física: um incluindo duas caminhadas lentas e duas caminhadas rápidas de 5 minutos e outro incluindo um circuito de atividades de vida diária (AVD) Concomitantemente, os pacientes utilizaram dois sensores de movimento: PW e SenseWear Armband (SAB, previamente validado para uso em pacientes com DPOC) Os desfechos do PW (contagem de passos [CP], gasto energético [GE], distância percorrida [DP], tempo de atividade [TA] e intensidade da caminhada [IC]) foram comparados ao vídeo e ao SAB como métodos critérios Resultados: As correlações entre o PW e os métodos critérios foram altas para a CP durante as caminhadas lentas e rápidas (r=,79 e ,95) e para GE durante a caminhada rápida (r=,83) A correlação foi mais modesta para GE durante a caminhada lenta (r=,65) e para DP e IC durante as duas velocidades (,47<r<,68) O aparelho foi reprodutível quanto ao registro de CP, DP e GE durante a caminhada lenta e para todas as variáveis durante a caminhada rápida (CCI>,79 para todas) Já durante o circuito de AVD, o PW subestimou em média 55% o TA, mas obteve uma estimativa aceitável do GE para o grupo como um todo (diferença média de 6% quando comparado ao SAB) Conclusões: Em pacientes com DPOC, o PW é reprodutível para a maioria dos seus desfechos e válido para a contagem de passos durante caminhadas lentas e rápidas e para estimativa do gasto energético durante caminhadas rápidas A validade do aparelho é mais limitada para estimar o gasto energético durante a caminhada lenta e a distância percorrida e intensidade da caminhada nas duas velocidades Durante a realização de AVDs, o PW subestima significativamente o tempo de atividade, mas fornece um estimativa aceitável do gasto energético no grupo como um todopt_BR
dc.description.abstractother1Abstract: Patients with chronic obstructive pulmonary disease (COPD) are considerably less active in daily life in comparison to healthy individuals The inactivity is associated with several complications of the disease, besides being the strongest predictor of mortality in patients with COPD Therefore, valid and economically affordable motion sensors for physical activity monitoring are needed Purpose: We aimed to evaluate the criterion validity and reproducibility of the Power Walker 61 motion sensor (PW) in patients with COPD Methods: Thirty patients with COPD (17 male, FEV1 44±17% predicted) were videotaped while performing two protocols of physical activity: one including two slow and two fast 5-minute walks, and another including a circuit of activities of daily living (ADL) Concomitantly, patients wore two motion sensors: PW and SenseWear Armband (SAB, previously validated in this population) Outcomes registered by PW (step counting [SC], energy expenditure [EE], walking distance [WD], activity time [AT] and walking intensity [WI]) were compared to video and SAB as criterion methods Results: Correlations between PW and the criterion method were high for SC during slow and fast walking (r=79 and r=95) and for EE during fast walking (r=83) Correlation was more modest for EE during slow walking (r=65) and for WD and WI during both speeds (47<r<68) The device was reproducible for registering SC, WD and EE during slow walking and for all variables during fast walking (ICC>79 for all) Furthermore, during the ADL circuit, PW significantly underestimated AT by an average of 55% but provided an acceptable EE estimation in a group basis (average difference of 6% with SAB) Conclusions: In patients with COPD, PW is reproducible for most outcomes and valid for step counting during slow and fast walking and energy expenditure during fast walking The device’s validity is more limited for energy expenditure during slow walking, and for walking distance and walking intensity at both speeds Furthermore, during the performance of ADL, PW significantly underestimates activity time but provides an acceptable estimation ofpt_BR
dc.description.notesDissertação (Mestrado em Ciências da Reabilitação) - Universidade Estadual de Londrina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Reabilitaçãopt_BR
dc.identifier.urihttps://repositorio.uel.br/handle/123456789/13821
dc.languagepor
dc.relation.coursedegreeMestradopt_BR
dc.relation.coursenameCiências da Reabilitaçãopt_BR
dc.relation.departamentCentro de Ciências da Saúdept_BR
dc.relation.ppgnamePrograma de Pós-Graduação em Ciências da Reabilitaçãopt_BR
dc.subjectPulmõespt_BR
dc.subjectExercícios físicospt_BR
dc.subjectPedômetropt_BR
dc.subjectValidadept_BR
dc.subjectCaminhadapt_BR
dc.subjectPhysical exercisespt_BR
dc.subjectPedometerspt_BR
dc.subjectWalkpt_BR
dc.subjectPatients - Motor capacitypt_BR
dc.subjectDiseases, Obstructivept_BR
dc.subjectValiditypt_BR
dc.subjectMonitoring patientspt_BR
dc.subjectLungspt_BR
dc.titleAvaliação de um novo sensor de movimento em pacientes com doença pulmonar obstrutiva crônicapt_BR
dc.typeDissertaçãopt_BR