Qualidade microbiológica da água e dialisatos em uma unidade de hemodiálise em Ponta Grossa - Pr

dataload.collectionmapped02 - Mestrado - Microbiologiapt_BR
dataload.filenamenourau157.pdfpt_BR
dataload.handlemapped123456789/25pt_BR
dataload.idpergamum105881pt_BR
dataload.idvirtuanourauvtls000111856pt_BR
dataload.idvirtuapergamumvtls000111856pt_BR
dataload.idvirtuapergamum.sameurlnourauSIMpt_BR
dataload.linknourauhttp://bibliotecadigital.uel.br/document/?code=vtls000111856pt_BR
dataload.linknourau.regularNÃOpt_BR
dataload.linknourau.retificadohttp://www.bibliotecadigital.uel.br/document/?code=vtls000111856pt_BR
dataload.linknourau.size60.00pt_BR
dc.contributor.advisorPelayo, Jacinta Sanchez [Orientador]pt_BR
dc.contributor.authorBorges, Cíntia Regina Mezzomopt_BR
dc.coverage.spatialLondrinapt_BR
dc.date.accessioned2024-05-01T12:42:07Z
dc.date.available2024-05-01T12:42:07Z
dc.date.created2004.00pt_BR
dc.date.defesa2004pt_BR
dc.description.abstractResumo: Objetivo: avaliar a qualidade bacteriológica de amostras de água e dialisatos em uma Unidade de Hemodiálise Metodologia e Resultados: 72 amostras de água e 72 de dialisatos foram coletadas no período de novembro de 23 a abril de 24 Foram realizadas as seguintes análises microbiológicas: pesquisa de coliformes totais e fecais, a qual resultou negativa para todas as amostras; contagem total de bactérias heterotróficas, onde três amostras de água e duas de dialisatos apresentaram contagens superiores aos limites permitidos pela legislação; pesquisa de endotoxina que revelou quantidades elevadas somente nas amostras de água que antecederam a Osmose Reversa Foram identificadas bactérias Gram-negativas não fermentadoras em 54 amostras de dialisatos e em 26 de água sendo que a maioria dos microrganismos pertencia aos gêneros: Pseudomonas (32,5%), Burkholderia (25%) e Acinetobacter (17,5%) Teste de adesão à superfície inerte, mostrou que várias bactérias são capazes de formar biofilme Algumas bactérias apresentaram resistência ao hipoclorito de sódio na concentração de 5 ppm, por 1 minutos (27%) e a três ou mais antimicrobianos (6%) Conclusões: os resultados sugerem que a água e dialisatos podem ser uma fonte de infecção para pacientes que necessitam de hemodiálise Significância e Impacto do Estudo: um adequado sistema de tratamento de água, desinfecção do sistema de hemodiálise e monitoramento microbiológico da água e dialisatos são necessários para a redução de surtos de bacteremia e pirogenia, melhorando a qualidade do serviço de hemodiálise e protegendo a saúde dos pacientespt_BR
dc.description.abstractother1Abstract: Aims: The objective of the study was to determine the bacteriological quality of samples of water and dialysate in a hemodialysis unit Methods and Results: Seventy-two samples of water and 72 of dialysate were collected in the period of November, 23 to April, 24 The following microbiological analyses were performed: test for total and fecal coliforms, which produced negative results for all the samples; counts of total heterotrophic bacteria, where three samples of water and two of dialysate showed levels higher than those permitted by national standards; and endotoxin assay which revealed high quantities only in samples of water that preceded reverse osmosis Non-fermenting Gram-negative bacteria were identified in 54 samples of dialysate and in 26 of water, in which the majority of the microorganisms belonged to the genera Pseudomonas (325%), Burkholderia (25%) and Acinetobacter (175%) The test for adhesion to an inert surface showed that various bacteria were capable of forming biofilms Some bacteria were resistant to sodium hypochlorite at a concentration of 5 ppm for 1 min (27%) and to three or more antibiotics (6%) Conclusions: Water and dialysate can be a source of infection for patients who need hemodialysis Significance and Impact of Study: An adequate system for water treatment, disinfection of the hemodialysis system and microbiological monitoring of the water and dialysate are necessary to reduce bacteremia and pyrogenia outbreaks, to improve the quality of the hemodialysis service and to protect the health of patientspt_BR
dc.description.notesDissertação (Mestrado em Microbiologia) - Universidade Estadual de Londrina, Centro de Ciências Biológicas, Programa de Pós-Graduação em Microbiologiapt_BR
dc.identifier.urihttps://repositorio.uel.br/handle/123456789/10384
dc.languagepor
dc.relation.coursedegreeMestradopt_BR
dc.relation.coursenameMicrobiologiapt_BR
dc.relation.departamentCentro de Ciências Biológicaspt_BR
dc.relation.ppgnamePrograma de Pós-Graduação em Microbiologiapt_BR
dc.subjectHemodiálisept_BR
dc.subjectÁguapt_BR
dc.subjectMicrobiologiapt_BR
dc.subjectHemodialysispt_BR
dc.subjectWater - Microbiologypt_BR
dc.titleQualidade microbiológica da água e dialisatos em uma unidade de hemodiálise em Ponta Grossa - Prpt_BR
dc.typeDissertaçãopt_BR

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
157.pdf
Tamanho:
711.63 KB
Formato:
Adobe Portable Document Format