Métodos eletroanalíticos sustentáveis para a determinação de 17ß-estradiol e triclosan empregando sensores impressos modificados com quantum dots de grafeno e nanopartículas de ouro

dc.contributor.advisorMedeiros, Roberta Antigo
dc.contributor.authorGalvão, Juliana Costa Rolim
dc.contributor.bancaDall’Antonia, Luiz Henrique
dc.contributor.bancaSantos, Jacqueline Ferreira Leite
dc.contributor.bancaOliveira, Geiser Gabriel de
dc.contributor.bancaLa Porta, Felipe de Almeida
dc.coverage.extent142 p.
dc.coverage.spatialLondrina
dc.date.accessioned2026-08-27T19:34:10Z
dc.date.available2026-08-27T19:34:10Z
dc.date.issued2026-03-23
dc.description.abstractA presença de contaminantes emergentes em matrizes ambientais e biológicas tem despertado crescente preocupação devido aos potenciais efeitos adversos à saúde humana e aos ecossistemas. Entre esses compostos, o 17ß-estradiol (E2) e o triclosan (TCS) destacam-se por sua ampla utilização em produtos farmacêuticos e de higiene pessoal, bem como por sua persistência no ambiente, mesmo após tratamentos convencionais de água. Neste trabalho, foram desenvolvidos dois métodos eletroanalíticos utilizando eletrodos de carbono impressos por serigrafia (SPE) modificados com nanomateriais e acoplados à voltametria de pulso diferencial para a determinação de E2 e TCS em diferentes amostras. No Capítulo 1, foi desenvolvido um SPE modificado com quantum dots de grafeno (QDGs), os quais foram sintetizados por diferentes métodos e técnicas. Dentre os QDGs avaliados, os obtidos por pirólise do ácido cítrico apresentaram melhor desempenho eletroquímico. O sensor apresentou faixa linear de 5,0 a 100,0 nmol L?¹ para E2, com LOD e LOQ de 0,24 e 7,28 nmol L?¹, respectivamente. Estudos de adição e recuperação em água do Lago Igapó e urina sintética apresentaram recuperação de 98%, e os resultados obtidos em amostras farmacêuticas foram concordantes com o método comparativo por CLAE. O método apresentou índice AGREE de 0,82, superior ao método comparativo (0,56). No Capítulo 2, foi desenvolvido um SPE modificado com nanopartículas de ouro (AuNPs) para a determinação de TCS. Após otimização por planejamento fatorial (2³), obteve-se um sensor com maior área ativa e melhor resposta eletroquímica. A faixa linear foi de 0,3 a 10,0 µmol L?¹, com LOD de 0,29 µmol L?¹ e LOQ de 0,97 µmol L?¹. As recuperações em amostras de água do Lago Igapó, água potável, água do Rio Medianeira e enxaguantes bucais variaram entre 97% e 103%, e os resultados também foram concordantes com os obtidos por CLAE. Os métodos propostos demonstraram ser alternativas simples, rápidas, sensíveis e mais sustentáveis, com menor consumo de solventes e energia, além de potencial para análises in situ, mostrando-se promissores para o monitoramento de contaminantes emergentes.
dc.description.abstractother1The presence of emerging contaminants in environmental and biological matrices has raised increasing concern due to their potential adverse effects on human health and ecosystems. Among these compounds, 17ß-estradiol (E2) and triclosan (TCS) stand out because of their widespread use in pharmaceutical and personal care products, as well as their persistence in the environment even after conventional water treatment processes. In this work, two electroanalytical methods were developed using screen-printed carbon electrodes (SPEs) modified with nanomaterials and coupled with differential pulse voltammetry for the determination of E2 and TCS in different samples. In Chapter 1, an SPE modified with graphene quantum dots (GQDs), synthesized by different methods and techniques, was developed. Among the evaluated GQDs, those obtained by citric acid pyrolysis showed the best electrochemical performance. The sensor exhibited a linear range from 5.0 to 100.0 nmol L?¹ for E2, with limits of detection (LOD) and quantification (LOQ) of 0.24 and 7.28 nmol L?¹, respectively. Recovery studies in Lake Igapó water and synthetic urine showed a recovery of 98%, and the results obtained for pharmaceutical samples were in agreement with those obtained by the comparative HPLC method. The method achieved an AGREE score of 0.82, higher than that of the comparative method (0.56). In Chapter 2, an SPE modified with gold nanoparticles (AuNPs) was developed for the determination of TCS. After optimization by factorial design (2³), a sensor with a higher active area and better electrochemical response was obtained. The linear range was 0.3 to 10.0 µmol L?¹, with LOD and LOQ values of 0.29 and 0.97 µmol L?¹, respectively. Recoveries in samples of Lake Igapó water, drinking water, Medianeira River water, and commercial mouthwashes ranged from 97% to 103%, and the results were also consistent with those obtained by HPLC. The proposed methods proved to be simple, fast, sensitive, and more sustainable alternatives, with lower solvent and energy consumption, as well as potential for in situ analyses, showing promise for the monitoring of emerging contaminants.
dc.identifier.urihttps://repositorio.uel.br/handle/123456789/19701
dc.language.isopor
dc.relation.departamentCCE - Departamento de Química
dc.relation.institutionnameUniversidade Estadual de Londrina - UEL
dc.relation.ppgnamePrograma de Pós-Graduação em Química
dc.subjectE2
dc.subjectTCS
dc.subjectSPE
dc.subjectAuNPs
dc.subjectQDGs
dc.subjectEletrodo modificado
dc.subjectVoltametria de pulso diferencial
dc.subjectQuímica
dc.subjectEstradiol
dc.subjectTriclosan
dc.subjectContaminantes emergentes
dc.subject.capesCiências Exatas e da Terra - Química
dc.subject.cnpqCiências Exatas e da Terra - Química
dc.subject.keywordsE2
dc.subject.keywordsTCS
dc.subject.keywordsAuNPs
dc.subject.keywordsGQDs
dc.subject.keywordsSPE
dc.subject.keywordsModified electrode
dc.subject.keywordsDifferential pulse voltammetry
dc.subject.keywordsChemistry
dc.subject.keywordsEstradiol
dc.subject.keywordsTriclosan
dc.subject.keywordsEmerging contaminants
dc.titleMétodos eletroanalíticos sustentáveis para a determinação de 17ß-estradiol e triclosan empregando sensores impressos modificados com quantum dots de grafeno e nanopartículas de ouro
dc.title.alternativeSustainable electroanalytical methods for the determination of 17ß-estradiol and triclosan employing printed sensors modified with graphene quantum dots and gold nanoparticles
dc.typeTese
dcterms.educationLevelDoutorado
dcterms.provenanceCentro de Ciências da Saúde

Arquivos

Pacote Original
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
CE_QUI_Dr_2026_Galvão_Juliana_CR.pdf
Tamanho:
2.83 MB
Formato:
Adobe Portable Document Format
Descrição:
Texto completo ID. 195495 Embargado até 19/05/2028
Nenhuma Miniatura disponível
Nome:
CE_QUI_Dr_2026_Galvão_Juliana_CR_Termo.pdf
Tamanho:
212.97 KB
Formato:
Adobe Portable Document Format
Descrição:
Termo de autorização
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
555 B
Formato:
Item-specific license agreed to upon submission
Descrição: