Medida de traços radioativos em amostras de leite em pó da região de Londrina - PR

dataload.collectionmapped02 - Mestrado - Físicapt_BR
dataload.filenamenourau412.pdfpt_BR
dataload.handlemapped123456789/52pt_BR
dataload.idpergamum18703pt_BR
dataload.idvirtuanourauvtls000010915pt_BR
dataload.idvirtuapergamumvtls000010915pt_BR
dataload.idvirtuapergamum.sameurlnourauSIMpt_BR
dataload.linknourauhttp://bibliotecadigital.uel.br/document/?code=vtls000010915pt_BR
dataload.linknourau.regularNÃOpt_BR
dataload.linknourau.retificadohttp://www.bibliotecadigital.uel.br/document/?code=vtls000010915pt_BR
dataload.linknourau.size60.00pt_BR
dc.contributor.advisorAppoloni, Carlos Roberto [Orientador]pt_BR
dc.contributor.authorMelquiades, Fábio Luizpt_BR
dc.contributor.bancaPortezan Filho, Otáviopt_BR
dc.coverage.spatialLondrinapt_BR
dc.date.accessioned2024-05-01T15:14:08Z
dc.date.available2024-05-01T15:14:08Z
dc.date.created2000.00pt_BR
dc.date.defesa00.02.2000pt_BR
dc.description.abstractResumo: Este trabalho consiste na medida de traços radioativos em leite em pó, através da espectrometria gama de alta resolução, utilizando um detector de GeHP de 1% de eficiência relativa, acoplado à eletrônica nuclear de medidas e a uma placa multicanal de 8192 canais Antes de iniciar as medidas, foram realizados alguns testes O primeiro deles para definir a blindagem a ser utilizada, fazendo várias medidas com diferentes blindagens de acordo com os materiais disponíveis, optando finalmente por uma blindagem com tijolos de chumbo de 1 cm, placas de ferro de 4 mm e de alumínio de 2 mm Em seguida foram testadas 4 geometrias diferentes de porta amostra, sendo que o béquer Marinelli de 2,1 litros totalmente preenchido é o que forneceu a melhor razão pico/fundo Ainda foi realizada uma inferência estatística para determinar a amostragem necessária para representar cada um dos lotes de leite a serem medidos, estabelecendo-se um número de 6 amostras, para uma confiabilidade de 95% Foram analisadas duas marcas de leite, Leite em Pó Integral Cativa e Leite em Pó Integral Polly As amostras foram devidamente acomodadas no béquer Marinelli de 2,1 L, lacradas e guardadas por 4 dias para atingir o equilíbrio secular A duração de cada medida foi de dois dias Foi possível identificar os radionuclídeos 4K, 137Cs e 232Th (a partir do 28Tl), cujas atividades foram calculadas de acordo com as normas da Agência Internacional de Energia Atômica (IAEA, 1989) A eficiência do detector foi medida utilizando amostras calibradas, preparadas a partir dos padrões certificados IAEA-326 e IAEA-375 Foram realizadas correções de auto-absorção, com base em medidas de amostras com diferentes densidades Os resultados obtidos para o leite em pó Cativa foram: 464 ± 12 Bq/kg para o 4K, 3,46 ± 1,5 e ,46 ± ,16 Bq/kg para as atividades mínimas detectáveis do 137Cs e do 232Th, respectivamente Para o leite Polly encontraram-se: 452 ± 1 Bq/kg para o 4K, 3,19 ± ,63 e ,32 ± ,12 Bq/kg para as atividades mínimas detectáveis do 137Cs e do 232Th, respectivamente As análises estatísticas realizadas comprovaram a repetitividade das medidas, através do teste de comparação de médias de Tukey Uma análise de correlação entre o desvio padrão e a média mostrou a ausência de erros sistemáticos significativos Comparando-se os resultados obtidos com outros trabalhos da literatura, comprovou-se que os valores das atividades encontradas estão dentro dos níveis normais de radioatividade para este produto e bem abaixo dos níveis máximos permissíveis estabelecidos pela CNEN, ou seja, as marcas de leite analisadas podem ser consumidas normalmente Por outro lado, a metodologia implementada apresentou um bom desempenho, face às condições experimentais disponíveispt_BR
dc.description.abstractother1Abstract: This work deals with the measurement of radioactive lines in powdered milk, with high resolution gamma spectrometry , using a HPGe detector with relative efficiency of 1%, coupled to the electronic nuclear chain and a multichannel card of 8192 channels Some tests were realized before beginning the measurements The first of them was to define the shield to be used, making several measures with different shields according to the available materials, opting finally for a shield composed of bricks of lead (1 cm thickness), plates of iron (4 mm thickness) and of aluminum (2 mm thickness) Four different geometries for the samples recipients were tested, and the Marinelli beaker of 2,1 liters totally filled was the one which supplied the best peak/background ratio A statistical inference was also realized to determine the sampling that represents each one of the lots of milk to be measured, resulting in a number of 6 samples, for a confidence level of 95% Two different kinds of powdered milk produced at Londrina were analyzed, Integral Powdered Milk Cativa and Integral Powdered Milk Polly The samples were properly put in the Marinelli beaker of 2,1 L, sealed and kept for 4 days to reach the secular equilibrium The counting time for each measurement was two days It was possible to identify the radionuclides 4K, 137Cs and 232Th (from 28Tl), whose activities were calculated according to the International Atomic Energy Agency norms (IAEA, 1989) The detector efficiency was measured using calibrated samples, prepared with the certified reference materials IAEA-326 and IAEA-375 Corrections for self-absorption were accomplished, based on measures of samples with different densities The results obtained for the powdered milk Cativa were: 464 ± 12 Bq/kg for 4K, 3,46 ± 1,5 and ,46 ± ,16 Bq/kg for the minimum detectable activities of 137Cs and 232Th, respectively For the milk Polly, the results were: 452 ± 1 Bq/kg for 4K, 3,19 ± ,63 and ,32 ± ,12 Bq/kg for the minimum detectable activities of 137Cs and 232Th, respectively The statistical analyses performed checked the measurements repeatability by means of the Tukey’s average comparison test A correlation analysis between standard deviations and the mean showed the absence of significant systematic deviation Comparing the results obtained with literature, it was demonstrated that the values of the activities found are within the normal levels of radioactivity for this kind of product and below the maximum permissible levels established by CNEN, that is, the analyzed milk can be normally consumed On the other hand, the implemented methodology presented a good performance, faced to the available experimental conditionspt_BR
dc.description.notesDissertação (Mestrado em Física) - Universidade Estadual de Londrina, Centro de Ciências Exatas, Programa de Pós-Graduação em Físicapt_BR
dc.identifier.urihttps://repositorio.uel.br/handle/123456789/16726
dc.languagepor
dc.relation.coursedegreeMestradopt_BR
dc.relation.coursenameFísicapt_BR
dc.relation.departamentCentro de Ciências Exataspt_BR
dc.relation.ppgnamePrograma de Pós-Graduação em Físicapt_BR
dc.subjectFísica nuclearpt_BR
dc.subjectRadioatividadept_BR
dc.subjectTécnicas e aplicações nuclearespt_BR
dc.subjectNuclear physicspt_BR
dc.subjectRadioactivitypt_BR
dc.titleMedida de traços radioativos em amostras de leite em pó da região de Londrina - PRpt_BR
dc.typeDissertaçãopt_BR

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
412.pdf
Tamanho:
2.45 MB
Formato:
Adobe Portable Document Format