Utilização de fone de ouvido durante aferição da pressão arterial em cães
| dc.contributor.advisor | Gava, Fábio Nelson | |
| dc.contributor.author | Silveira, Ana Paula Bina da | |
| dc.contributor.banca | Zanutto, Marcelo de Souza | |
| dc.contributor.banca | Matsubara, Lídia Mitsuko | |
| dc.coverage.extent | 49 p. | |
| dc.coverage.spatial | Londrina | |
| dc.date.accessioned | 2026-09-21T11:53:13Z | |
| dc.date.available | 2026-09-21T11:53:13Z | |
| dc.date.issued | 2025-07-14 | |
| dc.description.abstract | A pressão arterial é um parâmetro fisiológico fundamental para avaliar a saúde cardiovascular, sendo amplamente utilizada na prática clínica veterinária para o diagnóstico e acompanhamento de diversas condições. Em cães, a aferição da pressão arterial permite identificar alterações hemodinâmicas associadas a doenças como insuficiência renal, endocrinopatias e cardiopatias. Este estudo teve como objetivo principal avaliar o efeito do uso de fone de ouvido nas aferições da pressão arterial sistólica (PAS) realizadas por meio do método Doppler vascular indireto em cães. Além disso, buscou-se elaborar um folder informativo contendo diretrizes para a aferição da PAS com o uso do Doppler vascular, bem como orientações para a correta interpretação dos resultados obtidos. Foram selecionados 30 cães de propriedade de tutores que aceitaram participar da pesquisa, de diferentes idades, raças e sexos, da rotina de atendimento clínico de pequenos animais. A PAS foi aferida com e sem fone de ouvido, utilizando um delineamento cruzado randomizado. A adaptação ao ambiente foi considerada para minimizar os efeitos do estresse. Foram registradas as médias das sete aferições consecutivas de PAS, frequência cardíaca inicial, além do peso corporal dos animais. Houve diferença na aferição da PAS com fone de ouvido:(124,7 ± 17,79 mmHg), quando comparada com a aferição sem fone de ouvido (120,6 ± 17,47 mmHg). Não houve diferença quando comparada a ordem de aferição da PAS com ou sem fone. Os resultados indicaram maior precisão nas aferições com fone de ouvido, sugerindo que a utilização do fone reduz interferências ambientais e proporciona maior confiabilidade. Conclui-se que o uso de fone de ouvido acoplados ao Doppler vascular é uma abordagem eficaz para aumentar a acurácia diagnóstica | |
| dc.description.abstractother1 | Blood pressure is a fundamental physiological parameter for assessing cardiovascular health and is widely used in veterinary clinical practice for the diagnosis and monitoring of various conditions. In dogs, blood pressure measurement allows for the identification of hemodynamic changes associated with diseases such as renal failure, endocrinopathies, and heart diseases. The main objective of this study was to evaluate the effect of headphone use during systolic blood pressure (SBP) measurements using the indirect vascular Doppler method in dogs. Additionally, the study aimed to develop an informational leaflet containing guidelines for SBP measurement using vascular Doppler, as well as instructions for the correct interpretation of the results. Thirty client-owned dogs of various ages, breeds, and sexes, presented for routine small animal clinical care, were included in the study. SBP was measured with and without the use of headphones, employing a randomized crossover design. Environmental acclimation was considered to minimize stress-related effects. The mean values of seven consecutive SBP measurements were recorded, along with initial heart rate and body weight. A difference was observed in SBP measurements with headphones (124.7 ± 17.79 mmHg) compared to measurements without headphones (120.6 ± 17.47 mmHg). No difference was found when comparing the measurement order (with or without headphones). The results indicated greater precision in measurements taken with headphones, suggesting that their use reduces environmental interference and provides greater reliability. It is concluded that the use of headphones connected to the vascular Doppler device is an effective approach to enhance diagnostic accuracy | |
| dc.identifier.uri | https://repositorio.uel.br/handle/123456789/19979 | |
| dc.language.iso | por | |
| dc.relation.departament | CCA - Departamento de Clínicas Veterinárias | |
| dc.relation.institutionname | Universidade Estadual de Londrina - UEL | |
| dc.relation.ppgname | Programa de Pós-Graduação em Clínicas Veterinárias | |
| dc.subject | Doppler vascular | |
| dc.subject | Órgãos-alvo | |
| dc.subject | Fones de ouvido | |
| dc.subject | Monitoração hemodinâmica | |
| dc.subject | Cães | |
| dc.subject | Pressão arterial - Monitoração | |
| dc.subject.capes | Ciências Agrárias - Medicina Veterinária | |
| dc.subject.cnpq | Ciências Agrárias - Medicina Veterinária | |
| dc.subject.keywords | Vascular doppler | |
| dc.subject.keywords | Targetorgans | |
| dc.subject.keywords | Headphones | |
| dc.subject.keywords | Hemodynamic monitoring | |
| dc.subject.keywords | Dogs | |
| dc.subject.keywords | Blood pressure - Monitoring | |
| dc.title | Utilização de fone de ouvido durante aferição da pressão arterial em cães | |
| dc.title.alternative | Use of headphones during blood pressure measurement in dogs | |
| dc.type | Dissertação | |
| dcterms.educationLevel | Mestrado Profissional | |
| dcterms.provenance | Centro de Ciências Agrárias |
Arquivos
Pacote Original
1 - 2 de 2
Carregando...
- Nome:
- CA_VET_Me_2025_Silveira_Ana_PB.pdf
- Tamanho:
- 1.55 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
- Texto completo ID. 195993
Nenhuma Miniatura disponível
- Nome:
- CA_VET_Me_2025_Silveira_Ana_PB_Termo.pdf
- Tamanho:
- 33.04 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
- Termo de autorização
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 555 B
- Formato:
- Item-specific license agreed to upon submission
- Descrição: