Controle de um inversor monofásico conectado à rede elétrica com filtro LCL utilizando amortecimento ativo através de estimação de sinais

dataload.collectionmapped02 - Mestrado - Engenharia Elétricapt_BR
dataload.filenamenourau8497.pdfpt_BR
dataload.handlemapped123456789/208pt_BR
dataload.idpergamum21430pt_BR
dataload.idvirtuanourauvtls000235498pt_BR
dataload.idvirtuapergamumvtls000235498pt_BR
dataload.idvirtuapergamum.sameurlnourauSIMpt_BR
dataload.linknourauhttp://www.bibliotecadigital.uel.br/document/?code=vtls000235498pt_BR
dataload.linknourau.regularSIMpt_BR
dataload.linknourau.retificadohttp://www.bibliotecadigital.uel.br/document/?code=vtls000235498pt_BR
dataload.linknourau.size64.00pt_BR
dc.contributor.advisorSilva, Newton da [Orientador]pt_BR
dc.contributor.authorRomão, Arthur de Abreupt_BR
dc.contributor.bancaMelo, Leonimer Flávio dept_BR
dc.contributor.bancaSilva, Sérgio Augusto Oliveira dapt_BR
dc.coverage.spatialLondrinapt_BR
dc.date.accessioned2024-05-01T12:12:17Z
dc.date.available2024-05-01T12:12:17Z
dc.date.created2021.00pt_BR
dc.date.defesa11.11.2021pt_BR
dc.description.abstractResumo: Este trabalho apresenta o amortecimento ativo de um inversor monofásico conectado à rede elétrica, através do método de impedância virtual série, utilizando um estimador robusto às variações de parâmetros na obtenção do sinal de realimentação necessário para o amortecimento, contribuindo assim, não somente para a garantia de estabilidade do sistema, mas também para a capacidade de rejeição harmônica da corrente injetada na rede elétrica O inversor utiliza um filtro LCL e o controle de corrente é feito através da realimentação da corrente do lado da rede, com controladores proporcional-ressonante adaptativos em frequência e filtros para compensação harmônica Para implementação do amortecimento ativo é apresentada uma abordagem que utiliza um estimador de sinais para se obter a corrente do lado do conversor, evitando o aumento no número de sensores para aquisição da variável necessária O desempenho do amortecimento ativo e estimador proposto é observado através da modelagem matemática, análise de estabilidade a partir do lugar das raízes, erro de regime permanente e análise espectral do sinal de corrente, com a validação de simulações em MATLAB/Simulink e resultados experimentais obtidos com a utilização de um protótipopt_BR
dc.description.abstractother1Abstract: This work presents the active damping of a single-phase grid-tied inverter, by series vir tual impedance, using a robust estimator due to parameters variations in order to obtain the necessary feedback signal for the desired damping, thus contributing not only to en sure system stability, but also for the harmonic rejection capability of the power grid injected current The inverter uses an LCL filter and the current control is done through the grid-side current feedback, with frequency adaptive proportional-resonant controllers and filters for harmonic compensation To implement the active damping, an approach that uses a signal estimator to obtain the converter-side current is presented, avoiding the increase in the number of sensors to acquire the necessary variable The performance of the active damping and proposed estimator is observed through mathematical model ing, stability from the root locus, steady state error and spectral analysis of the current signal, with the validation of simulations in MATLAB/Simulink and experimental results obtained with the use of a prototypept_BR
dc.description.notesDissertação (Mestrado em Engenharia Elétrica) - Universidade Estadual de Londrina, Centro de Tecnologia e Urbanismo, Programa de Pós-Graduação em Engenharia Elétricapt_BR
dc.identifier.urihttps://repositorio.uel.br/handle/123456789/9838
dc.languagepor
dc.relation.coursedegreeMestradopt_BR
dc.relation.coursenameEngenharia Elétricapt_BR
dc.relation.departamentCentro de Tecnologia e Urbanismopt_BR
dc.relation.ppgnamePrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.subjectEngenharia elétricapt_BR
dc.subjectEletrônica de potênciapt_BR
dc.subjectRejeição harmônicapt_BR
dc.subjectEnergia renovávelpt_BR
dc.subjectFiltros elétricos ativospt_BR
dc.subjectElectric engineeringpt_BR
dc.subjectPower electronicspt_BR
dc.subjectHarmonic rejectionpt_BR
dc.subjectRenewable energypt_BR
dc.subjectElectric filters, Activept_BR
dc.titleControle de um inversor monofásico conectado à rede elétrica com filtro LCL utilizando amortecimento ativo através de estimação de sinaispt_BR
dc.typeDissertaçãopt_BR

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
8497.pdf
Tamanho:
3.07 MB
Formato:
Adobe Portable Document Format